Boiler Treat One Shot - 25L, Make:Vecom

In stock
SKU
1601100023
Quick Enquiry

Vecom Marine offers various effective products for water treatment. These include products for conditioning cooling water and boiler water, preventing scale formation and corrosion, neutralising pH, etc. We have a full range of test kits for determination of alkalinity, chloride, nitrite, DEHA, phosphate and hardness.

Applications - BOILER TREAT ONE SHOT is suitable for use with all auxiliary boilers including waste heat and exhaust gas boilers. BOILER TREAT ONE SHOT prevents scale formation

Direction for use- or optimum results, BOILER TREAT ONE SHOT should be dosed directly into the boiler via a by-pass pot feeder installed in the boiler feed line. For low-pressure boilers without by-pass feeder, the product may be dosed into the hot well. But we do not advise this as a long term solution. Regular blowdown is necessary to remove sludge and solids.

In order to treat the boiler correctly, five elements are needed.

Alkaline controller and corrosion inhibitor – ALKALINITY CONTROL

Scale suppression and prevention – HARDNESS CONTROL LIQUID

Particle removal – LIQUID COAGULANT

Oxygen scavenging – HYDRAZIDE

Condensate conditioning or neutralising – CONDENSATE TREAT

BOILER TREAT ONE SHOT has two elements of treatment:

Alkaline controller and corrosion inhibitor

Scale suppression and prevention

Initial dosage

Initial dose for untreated system is 1 l of BOILER TREAT ONE SHOT per 1000 l of water. Maintenance dosages are determined by the result of P-alkalinity. Analysis is carried out using VECOM MARINE boiler water test kits.

NOTE: The phosphate and alkalinity values if analysed, may not necessarily correspond to the control levels. In cases of poor quality feedwater used, increased dosages may be required. If the P-alkalinity is persistently low, use ALKALINITY CONTROL to adjust. The pH of the boiler water should be kept between 9.5 – 11.

The boiler water parameters should be as per the boiler operating manual. Our recommendations are:
P-alkalinity: 100 – 200 ppm CaCO3 (ideal level P-alkalinity is 150 ppm)
M-alkalinity: Below two times P-alkalinity
Boiler chloride: Max. 90 ppm
Boiler pH: 9.5 – 11.0
Condensate pH: 8 – 10
Oxygen scavenger: 0.8 – 1.5 ppm

More Information
SKU 1601100023
Brand Vecom
Customer Questions
No Questions
Please, mind that only logged in users can submit questions
More from Vecom
  1. FOT Sludge Dispersant-25L, Make:Vecom
    FOT Sludge Dispersant-25L, Make:Vecom
    Quick Enquiry
  2. FOT LI 4100-25L, Make:Vecom
    FOT LI 4100-25L, Make:Vecom
    Quick Enquiry
  3. Cooltreat NCLT - 25L, Make:Vecom
    Cooltreat NCLT - 25L, Make:Vecom
    Quick Enquiry
  4. Valve Treat, Make:Vecom
    Valve Treat, Make:Vecom
    Quick Enquiry